India panel air conditioned computer cabinets
are designed to provide a thermally
conditioned environment for the reliable operation
of the housed computers, servers and other
IT equipment.
Working concept of Hanut India panel air conditioned
computer cabinets
The computer
cabinet is equipped with one panel conditioner
and one or two exhaust fans.
During summer
season the panel conditioner will maintain
the rack’s temperature below 30 degree
C. When the panel
conditioner is working the exhaust fan(s)
are kept switched off.
During cooler
part of the year when the room temperature
is below 30 degree C the panel air conditioner
is switched off and
exhaust fan(s) are turned on. Exhaust fan(s)
expel hot air from the rack thereby maintaining
the computer cabinet's temperature
below 35 degree C.
This smart
use of panel air conditioner and exhaust
fan saves electricity and prolongs the life
of the panel conditioner.
Hanut India
air conditioned computer racks thus provides
a thermally conditioned environment for
reliable operation of the
housed IT equipment at minimal cost.
Unique features of Hanut India panel air
conditioned computer cabinets
To improve insulation and cooling efficiency
the rack’s inside is covered with
insulating foam of thickness 10mm (minimum).
Panel conditioner is attached to the rack
without ducting. Direct attachment i.e.
no ducting means better cooling and minimal
chances of cold air escaping from the rack.
Panel conditioner can be easily removed
and reattached to the rack allowing for
easy maintenance.
Success of an air conditioned computer
rack depends significantly on the quality
of the panel air conditioner (AC) used.
Hanut India has tie up with two of the leading
panel AC manufacturers in India enabling
it to offer premium quality panel ACs
with its air conditioned computer racks.
Information
on the panel air conditioned computer cabinet
shown
This
cabinet was designed to provide a thermally
conditioned environment to a server and
a PC. Using Hanut India portable
2 port kvm switch only a single keyboard,
mouse and monitor were required to manage
the server and the PC.
765mm high × 1000mm wide × 700mm
deep rack.
Space saving SPLIT front door with 2 point
locking arrangement
Lockable and removable rear and side panels
One 4" exhaust fan
Rack basic frame made from MIG welded 2mm
thick CRCA sheet steel
Panel air conditioner with cooling capacity:
950Kcal (approx. 0.3 tons)
Govt. approved environment friendly refrigerating
gas.
Branded compressor - Kirloskar / Tushkumesh
/ Dishik make compressor.
Minimal onsite routine maintainace is required
Application
in Industry and rural bank branches
Hanut India panel air conditioned
computer cabinets are cost effective alternative
to traditional
approach of building a dedicated computer
room with room air conditioner.
Request
a copy of our white paper highlighting
the significant advantages of air conditioned
computer cabinets over
dedicated computer rooms with room air conditioners.
Customers
in India: State Bank of Bikaner and Jaipur
(SBBJ), State Bank of Hyderabad,…
In
addition to the computer cabinet shown above
Hanut India offers 2 other tested air conditioned
computer cabinet configurations.
Hanut India can also custom build computer
cabinets as per customer’s specifications
and/or requirements.